Contrôleur de feux de circulation LEDbow IOT

Jk-d3 coordinated adaptive signal controller is a terminal control device used to control traffic lights in traffic signal control systems. The signal control scheme can be set and the traffic lights can be controlled through the touch panel. It can also be connected to the traffic signal control network to receive and process the signal control scheme from the traffic signal control platform remotely and control the signal lamp to execute instructions.

Les détails du produit

Étiquettes de produit

détails du produit

Jk-d3 coordinated adaptive signal controller is a terminal control device used to control traffic lights in traffic signal control systems. The signal control scheme can be set and the traffic lights can be controlled through the touch panel. It can also be connected to the traffic signal control network to receive and process the signal control scheme from the traffic signal control platform remotely and control the signal lamp to execute instructions.

It supports routing function, flexible peripheral IOT equipment access, and can be used as an IoT edge computing gateway at the intersection of a smart city.
This control mechanism is a full-function signal machine designed and manufactured according to the China standard.

Détails du produit (Réf.) (Personnalisé)

Timing scheme Support 32 timing schemes
Time period configuration Support 48 time periods
Special date Support 32 special dates and 7 weeks configuration (Monday to Sunday)
Data interface 2 RS232 serial ports, 2 RS485 ports, 4 Ethernet ports, 2 USB ports
Surge protection Power supply lightning protection, network lightning protection
Remote control function: A mobile terminal, side panel, remote control, cloud platform control.
Power supply Rated voltage of signal power supply: AC220V ± 20%, 50Hz ± 2Hz, and AC220V power backup socket is installed in the cabinet
Driving power 36W
Power consumption of the whole machine ≥50w(excluding LCD screen)
La resistance d'isolement The insulation resistance of the signal is greater than 100m Ω
Rigidité diélectrique Apply 1500V, 50Hz voltage between the power electrode or other conductive circuits connected with the power electrode, cabinet, installation cabinet, and other accessible parts, without breakdown.
Working temperature range -40~+70℃
Humidité Relative humidity of normal operation: 10% – 95% (no condensation)
Waterproof It has passed the rain test and works normally during and after the test. There is no water seepage or ponding inside the signal controller cabinet
Dustproof The traffic signal controller works normally during and after the dust test, and there is no large amount of dust in the signal controller cabinet
Rustproof The signal controller works normally after salt spray test, and the metal parts such as the signal controller cabinet and internal frame are not seriously rusted
IP rate IP55
Specification and size 700mm×510mm×1410mm

Termes de l'échange
MOQ 1 PCS (exemple de service)
Détails du forfait Selon la dimension d'affichage
détail de livraison 25-35 jours après le dépôt
Modalités de paiement T / T (30% à l'avance, 70% avant expédition)

Features:

1. Meet the requirements of gb25280-2016 Level C, support NTCIP communication protocol; support special date, multi-period,multi-phase scheme configuration; standard 48 channel output, maximum 108 channel output;

2.Beidou/GPS dual-mode timing and positioning;

3. Adopting cortex-a57 64 bit microprocessor, it can support complex operation and realize powerful real-time communication function;

4.Wired and wireless flexible networking, support dual network support, and online at the same time;

5. It supports multiple traffic detection data access such as microwave, video, radar, etc. and adaptive variable lane control according to the length of queuing vehicles;

6. Wireless remote control, manual emergency control function, support yellow flash, all red, light off, forced release and other signal control functions;

7.Pedestrian crossing button, BRT bus priority, emergency vehicle priority control; support single adaptation, trunk green wave, regional adaptation;

8.Real-time fault detection and system log recording function, automatic fault degradation processing function;

9.Signal lamp level abnormal, fault detection, automatic feedback;| Automatic detection of phase green conflict;

10. Support independent yellow flash;

11.Support pulse and communication countdown;

12.LCD touch screen, human-computer interface;

13. Data is automatically saved in case of power failure;

14.Dual hot standby, automatic switching;

15. It supports routing function, flexible peripheral IOT equipment access, and is used for IoT edge computing gateway of smart city intersection;

16. The traffic signal output based on DSRC protocol can provide support for people and vehicles.

[template id=”245″]

FAQ

Q1: Êtes-vous un fabricant ou une société commerciale?

A1: Nous sommes fabricant et notre usine est située à Foshan, province du Guangdong, nous avons également notre propre équipe de R&D. Bienvenue à nous rendre visite!

Q2. Puis-je avoir un exemple de commande pour IoT Traffic Signal Controller?

A: Oui, nous nous félicitons de l'ordre d'échantillon pour tester et vérifier la qualité. Les échantillons mélangés sont acceptables.

Q3: Peut tu fournir des services de conception personnalisés selon un concept ou un dessin?

A2: Oui, nous sommes un fabricant flexible, et en ce qui concerne les caractéristiques de nos produits, nous pouvons fournir des produits personnalisés, vous n'avez qu'à fournir vos besoins ou un dessin détaillé que nous pouvons produire pour vous.

Q4. How to proceed with an order for IoT Traffic Signal Controller?

R: Tout d'abord, faites-nous part de vos besoins ou de votre application.
Deuxièmement, nous citons selon vos besoins ou nos suggestions.
Troisièmement, le client confirme les échantillons et dépose une caution pour la commande formelle.
Quatrièmement, nous organisons la production.

Q5: Offrez-vous une garantie pour les produits?

R: Oui, nous offrons 2 ans de garantie sur nos produits.

Q6: Comment résoudre les problèmes de qualité après-vente?

R: Veuillez fournir les détails du problème. Nous vous proposerons une solution satisfaisante dans les 24 heures suivant la confirmation des problèmes.

Envoyez-nous votre message:

ENQUÊTE MAINTENANT
ENQUÊTE MAINTENANT